C-more micro EA1-S6MLW Manual do Utilizador Página 16

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 19
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 15
C
C
C
-
-
-
m
m
m
o
o
o
r
r
r
e
e
e
M
M
M
i
i
i
c
c
c
r
r
r
o
o
o
-
-
-
G
G
G
r
r
r
a
a
a
p
p
p
h
h
h
i
i
i
c
c
c
P
P
P
a
a
a
n
n
n
e
e
e
l
l
l
November 2010 16/19
COMPONENTS - SPARE PARTS - TECHNICAL SERVICES
AMA-AUTOMATION GMBH | Stuttgarter Str. 13 | D-75179 Pforzheim | Telefon +49 7231 78 61 11 | contac[email protected]m | www.ama-automation.com
Registergericht Mannheim, HRB-Nr. 712160 | Geschäftsführung: Irmhild Maschka | Z E R T I F I Z I E R T N A C H D I N I S O E N 9 0 0 1 : 2 0 0 8
C-more
Micro-Graphic PLC Communication - Protocols & Cabling Chart
PLC C-more 4’’ and 6’’ Micro-Graphic Panel
** PLC Port Powered or
External DC Power Supply
External DC Power Supply
Panel Port1 - RJ12 Panel Port2 - DB15
Family
CPU Port & Type
Protocol(s)
Supported
Cables &
Network Type
Protocol(s)
Supported
Cables &
Network Type
Port1
RJ12
all versions
Port2
RJ12
DV-1000CBL **
RS-232
EA-2CBL
RS-232
CLICK
Analog CPUs Port3
AutomationDirect
Modbus (CLICK)
nicht möglich
AutomationDirect
Modbus (CLICK)
RS-485 *
RS-232
DV-1000CBL
**
RS-232
EA-2CBL
RS-232
Productivity
all versions
RS-485
AutomationDirect
Productivity3000
(P3-550)
nicht möglich
AutomationDirect
Productivity3000
(P3-550)
RS-485
*
Port1
RJ12
all versions
Port2
RJ12
K-sequence
Direct
NET
Modbus RTU
DV-1000CBL **
RS-232
K-sequence
Direct
NET
Modbus RTU
EA-2CBL
RS-232
Port1
RJ12
DV-1000CBL **
RS-232
EA-2CBL
RS-232
EA-2CBL-1
RS-232
K-sequence
Direct
NET
Modbus RTU
RS-422 *
Direct
LOGIC
DL05
D0-DCM
Port2
DB15HD
K-sequence
Direct
NET
Modbus RTU
DV-1000CBL **
+ FA-15HD
RS-232
Modbus RTU
RS-485 *
only Modbus
Port1
RJ12
DV-1000CBL
**
RS-232
EA-2CBL
RS-232
EA-2CBL-1
RS-232
K-sequence
Direct
NET
Modbus RTU
RS-422
*
all versions
Port2
DB15HD
K-sequence
Direct
NET
Modbus RTU
DV-1000CBL
**
+ FA-15HD
RS-232
Modbus RTU
RS-485
*
only Modbus
Port1
RJ12
DV-1000CBL
**
RS-232
EA-2CBL
RS-232
EA-2CBL-1
RS-232
K-sequence
Direct
NET
Modbus RTU
RS-422
*
Direct
LOGIC
DL06
D0-DCM
Port2
DB15HD
K-sequence
Direct
NET
Modbus RTU
DV-1000CBL
**
+ FA-15HD
RS-232
Modbus RTU
RS-485
*
only Modbus
Direct
LOGIC
DL105
all versions
Port1
RJ12
K-sequence
DV-1000CBL **
RS-232
K-sequence
EA-2CBL
RS-232
* Note 1:
See the C-more 6” Micro-Graphic Hardware User Manual (EA1-MG6-USER-M), Chapter 6: PLC Communications, for
wiring diagrams that the user can use to construct their own cables.
** Note 2:
The PLC can provide 5 VDC through this cable. No external 12-24 VDC souce is required, however, screen brightness
is diminished and the alarm beep will not function.
Vista de página 15
1 2 ... 11 12 13 14 15 16 17 18 19

Comentários a estes Manuais

Sem comentários