Operator Interface
C-more 6” Micro-Graphic PLC Connections
Cabling requirements
When using the built in RJ12 serial port (Port1) on the
C-more 6” Micro-Graphic panel to connect with the DL05,
DL06, DL105, DL205, D3-350 and DL405 CPUs, your
cabling choices are fairly simple.
• DV-1000CBL — connects to DL05, DL06, DL105, DL205, D3-350
and D4-450 phone jack.
• D4-1000CBL — connects to all DL405 CPU 15-pin ports.
A maximum cable length of 10 feet between the
C-more Micro-Graphic panel and the PLC is recommended
when powering the panel in Low-Power Mode from the PLC.
The C-more 6” Micro-Graphic panel can also communi-
cate through its built-in 15-pin serial port (Port2) via RS-
232, RS-422 and RS-485 using these cables.
• EA-2CBL — connects to DL05, DL105, DL205, D3-350 and D4-
450 phone jack.
• EA-2CBL-1 — connects to D2-250, D250-1, D2-260, DL06 VGA
connector.
PLC Supported Protocols
• DirectLOGIC K-sequence
• DirectNET
• Modbus (Koyo Addressing)
• Modbus RTU
• Entivity Modbus RTU
• Allen-Bradley DF1 Half Duplex
• Allen-Bradley DF1 Full Duplex
• Allen-Bradley PLC5 DF1
• Allen-Bradley DH485
• GE Fanuc SNPX (90/30, 90/70, Micro 90, VersaMax Micro)
• Omron Host Link (C200 Adapter, C500)
• Omron FINS Serial (CJ1, CS1)
• Mitsubishi Melsec FX
• Siemens PPI
C-more 6” Micro-Graphic Port 1 to DL05 PLC Port 2
C-more 6” Micro-Graphic Port 2 to DL06 PLC Port 2