C-more micro EA1-S6MLW Manual do Utilizador Página 1

Consulte online ou descarregue Manual do Utilizador para Unidades de distribuição de energia (PDUs) C-more micro EA1-S6MLW. C-more micro EA1-S6MLW User manual Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 0
Hardware User Manual
EA1-MG6-USER-M
®
6-inch Micro-Graphic Panel
C-more 6” Micro-Graphic Panel
EA1-S6MLW - shown in Landscape Mode
C-more 6” Micro-Graphic Panel Installed in a
20-button Landscape Keypad Bezel EA-MG6-BZ2
C-more 6” Micro-Graphic Panel
EA1-S6ML - shown in Portrait Mode
C-more 6” Micro-Graphic Panel Installed in a
21-button Portrait Keypad Bezel EA-MG6-BZ2P
Vista de página 0
1 2 3 4 5 6 ... 188 189

Resumo do Conteúdo

Página 1 - 6-inch Micro-Graphic Panel

Hardware User ManualEA1-MG6-USER-M®6-inch Micro-Graphic PanelC-more 6” Micro-Graphic PanelEA1-S6MLW - shown in Landscape ModeC-more 6” Micro-Graphic P

Página 2

Chapter 2: Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2–1Available Models . . . . . . . . . . . . . . . . .

Página 3 - HARDWARE USER MANUAL

6–12Chapter 6: PLC Communications6®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10DirectLOGIC DL405 PLCs and D4-DCM ModulePanel Powered via

Página 4

6–13Chapter 6: PLC Communications6Allen-Bradley PLCsPanel Powered via external power supply, Port1 or Port2 CommunicationsPLC Compatibility & Conn

Página 5 -  WARNING 

6–14Chapter 6: PLC Communications6®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10GE, Mitsubishi, Omron, Modicon and Siemens PLCsPanel Power

Página 6 - ADVERTENCIA

6–15Chapter 6: PLC Communications6Cables from AutomationDirectPart No. EA-3CBLPart No. EA-4CBL-1Part No. EA-4CBL-2Part No. EA-2CBL-1Part No. EA-2CBLEA

Página 7 - Marques de commerce

6–16Chapter 6: PLC Communications6®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Cables from AutomationDirect (cont’d)Part No. D4-1000CBLPa

Página 8

6–17Chapter 6: PLC Communications6EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®Cables from AutomationDirect – Wiring DiagramsThe followin

Página 9 - TABLE OF CONT ENTS

Cables from AutomationDirect – Wiring Diagrams (cont’d)Direct LOGIC:Direct Logic PLC 15-pin D-sub port: DL405,RS-232C (p/n EA-4CBL-1)8 = do not used7

Página 10 - Table of Contents

6–19Chapter 6: PLC Communications6Cables from AutomationDirect – Wiring Diagrams (cont’d)Direct LOGIC:Direct Logic PLC 25-pin D-sub port: DL405, D3-35

Página 11

6–20Chapter 6: PLC Communications6®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Cables from AutomationDirect – Wiring Diagrams (cont’d)Not

Página 12

6–21Chapter 6: PLC Communications6Cables from AutomationDirect - Wiring Diagrams (cont’d) Allen-Bradley:Allen-Bradley MicroLogix™ 1000/1100/1200/1500R

Página 13

Memory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5–6Protocol . . . . . . . .

Página 14

6–22Chapter 6: PLC Communications6®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Cables from AutomationDirect - Wiring Diagrams (cont’d)All

Página 15 - GETTING STARTE D

Cables from AutomationDirect - Wiring Diagrams (cont’d)Allen-Bradley:6–23Chapter 6: PLC Communications6C-more6” Micro-GraphicPanel Port2C-more6” Micro

Página 16

Cables from AutomationDirect - Wiring Diagrams (cont’d)GE:Mitsubishi:Mitsubishi FX Series 25-pin D-sub port,RS-422A (p/n EA-MITSU-CBL)To PLC25-Pin Por

Página 17 - Conventions Used

6–25Chapter 6: PLC Communications6Cables from AutomationDirect - Wiring Diagrams (cont’d)Mitsubishi:Omron:Mitsubishi FX Series 8-pin MINI-DIN,RS-422A

Página 18 - Agency Approvals

6–26Chapter 6: PLC Communications®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10User Constructed Cables – Wiring DiagramsDiagram 1Diagram 2

Página 19 - Product Label Example:

6–27Chapter 6: PLC Communications6EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®User Constructed Cables – Wiring Diagrams (cont’d)Diagram

Página 20 - Quick Start Steps

6–28Chapter 6: PLC Communications6®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10User Constructed Cables – Wiring Diagrams (cont’d)Diagram

Página 21 - Optional Accessory

6–29Chapter 6: PLC Communications6EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®User Constructed Cables – Wiring Diagrams (cont’d)Diagram

Página 22

User Constructed Cables – Wiring Diagrams (cont’d)Diagram 9Diagram 106–30Chapter 6: PLC Communications6®EA1-MG6-USER-M Hardware User Manual, 1st Ed. R

Página 23

User Constructed Cables – Wiring Diagrams (cont’d)Diagram 11Diagram 126–31Chapter 6: PLC Communications6EA1-MG6-USER-M Hardware User Manual, 1st Ed. R

Página 24 - Enclosure Clearances

User Constructed Cables – Wiring Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6–26RS-422A/RS-485A Multi-Drop Wiring Diagram Exam

Página 25

User Constructed Cables – Wiring Diagrams (cont’d)Diagram 13Diagram 146–32Chapter 6: PLC Communications6®EA1-MG6-USER-M Hardware User Manual, 1st Ed.

Página 26

6–33Chapter 6: PLC CommunicationsEA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®User Constructed Cables – Wiring Diagrams (cont’d)Diagram 1

Página 27 - Communications Cable

6–34Chapter 6: PLC Communications6®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®®RS-422A/RS-485A Multi-Drop Wiring Diagram ExamplesNote:

Página 28 - SETUP MENU

6–35Chapter 6: PLC Communications6EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®RS-422A/RS-485A Multi-Drop Wiring Diagram Examples (cont’d

Página 29 - Available PLC Protocols

6–36Chapter 6: PLC Communications6®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®®RS-422A/RS-485A Multi-Drop Wiring Diagram Examples (cont

Página 30 - DV 1000CBL

6–37Chapter 6: PLC Communications6EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®RS-422A/RS-485A Multi-Drop Wiring Diagram Examples (cont’d

Página 32 - Available Models

77MA IN TENA NCECHCHAPTERCHAPTERIn This Chapter...Project Backup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 33 - Model Specifications

MaintenanceAlthough the C-more®6” Micro-Graphic panels require very little maintenance, setting upa routine maintenance schedule will insure the longe

Página 34 - Model Specifications (cont’d)

Check Transmit and Receive IndicatorsDuring a routine maintenance check is a good time to take a quick look at the status indicatorson the back of the

Página 35 - Panel Dimensions

Customizing the Function Keys Insert Label . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9–3Appendix A: PLC Protocol Error Codes . . .

Página 36 - Communications Ports

Run Tests under the System Setup ScreensUse the C-more 6” Micro-Graphic panel’s System Setup Screens to test communication ports,PLC connectivity, the

Página 37 - Chemical Compatibility

Check Settings under the System Setup ScreensUse the C-more 6” Micro-Graphic panel’s System Setup Screens to check the various settingssuch as the LCD

Página 38 - Chapter 2: Specifications

Check Project FunctionalityDuring a routine maintenance schedule is a good time to check the functionality of yourapplication, making sure that variou

Página 39

Notes:7–7Chapter 7: Maintenance7EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®

Página 41

88TROUBL ESHOOT INGCHCHAPTERCHAPTERIn This Chapter...C-more 6” Micro-Graphic Panel does not Power up . . . . . . . . . . . . . . . . . . . . . . . .8

Página 42

TroubleshootingThe following are some problems that may be encountered during the installation andoperation of your C-more®Micro-Graphic panel. We hav

Página 43

Display is DimNOTE: When the panel is powered through Port1 from a connected PLC or PC, the screen brightness isdiminished because the panel is runnin

Página 44

Lost Firmware – Red ‘Update Mode’ Screen DisplayedIf the C-more Micro-Graphic panel’s firmware becomes corrupted or for some reason is lostfrom the pa

Página 45

8–5Chapter 8: Troubleshooting8EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®No Communications between Panel and PC (Personal Computer)Ther

Página 47 - ACCESSORIES

8–6Chapter 8: Troubleshooting®8EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10No Communications between Panel and PC (Personal Computer) (co

Página 48 - Accessories

8–7Chapter 8: Troubleshooting8EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®No Communications between Panel and PLCThe C-more Micro-Graphi

Página 49 - Chapter 3: Accessories

Panel & PLC Error CodesThe C-more Micro-Graphic panel includes built-in PLC communication protocol diagnosticsthat monitor the exchange of data be

Página 50

C-more Micro-Graphic Panel Runtime ErrorsThe C-more Micro-Graphic panel includes built-in diagnostics that check for proper operationof the panel when

Página 51

Electrical Noise ProblemsMost noise problems result from improper grounding of the system. A good earth ground canbe the single most effective way to

Página 52 - Converter Status LEDs

99REPLACEMENT PARTSCHCHAPTERCHAPTERIn This Chapter...Replacement Parts Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 53

Replacement Parts OverviewReplacement Parts9–2Chapter 9: Replacement Parts®9EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Part Number Descr

Página 54 - Panel Cutout

9–3Chapter 9: Replacement Parts9EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®Customizing the Function Keys Insert Label4.803[122.0]0.563[

Página 56

APAPPENDIXAPPENDIXAAIn This Appendix...Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 57

11GETTING STARTE DCHCHAPTERCHAPTERIn This Chapter...Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 58

AIntroductionThe C-more®Micro-Graphic panels are capable of communicating over RS232, RS422 andRS485 serial networks. They communicate with CLICK PLC’

Página 59

C-more Micro-Graphic Panel Error Code TableThe following table includes all of the error codes and error messages that the panel will displayif the li

Página 60 - IOIOI – PLC

C-more Micro-Graphic Panel Error Code Table (cont’d)Modbus Protocols Error Code P499 ExplanationThe following table lists the errors that can be gener

Página 61 - Clear Screen Overlay

DirectLOGIC Error Code P499 ExplanationThe P499 error code is used to show any errors that are generated by the connected PLC. TheP499 error message i

Página 62

Allen-Bradley Error Code P499 ExplanationThe P499 error code is used to show any errors that are generated by the connected PLC. TheP499 error message

Página 63 - INSTALLATION & WIRING

Allen-Bradley DF1 Protocol – PLC Error Code TablesThe following PLC error tables cover possible errors that are detected by the panel from Allen-Bradl

Página 64 - Safety Guidelines

Allen-Bradley DF1 Protocol – PLC Error Code Tables (cont’d)PLC Errors for Allen-Bradley DF1 Protocol, EXT STS Command Code for F0 CommandPanel Error C

Página 65

Allen-Bradley DH485 Protocol – PLC Error Code TablesThe following PLC error code tables cover possible errors that are detected by the panel fromAllen

Página 66 - MODEL EA1 S6M W

Allen-Bradley DH485 Protocol – PLC Error Code Tables (cont’d)PLC Errors for Allen-Bradley DH485 Protocol, EXT STS Command Code for F0 CommandPanel Err

Página 67 - Wiring Guidelines

GE Error Code P499 ExplanationThe P499 error code is used to show any errors that are generated by the connected PLC. TheP499 error message includes a

Página 68 - Wiring Guidelines (cont’d)

IntroductionThe Purpose of this ManualThank you for purchasing from our C-more®Micro-Graphic family of products. This manualdescribes AutomationDirec

Página 69 - 50 feet [15.0 m] Maximum

AGE SNPX Protocol – PLC Error Code TablesThe following table lists the errors that can be generated by the GE 90-30, 90-70 and VersaMaxPLC when using

Página 70

GE SNPX Protocol – PLC Error Code Tables (cont’d)(PLC generated error codes for the GE 90-30, 90-70 and VersaMax SNPX protocolcontinued on the next pa

Página 71 - SYSTEM SETUP SCREENS

GE SNPX Protocol – PLC Error Code Tables (cont’d)(PLC generated error codes for the GE 90-30, 90-70 and VersaMax SNPX protocolcontinued on the next pa

Página 72

GE SNPX Protocol – PLC Error Code Tables (cont’d)(PLC generated error codes for the GE 90-30, 90-70 and VersaMax SNPX protocolcontinued on the next pa

Página 73 - Micro-Graphic

GE SNPX Protocol – PLC Error Code Tables (cont’d)(PLC generated error codes for the GE Fanuc 90-30, 90-70 and VersaMax SNPX protocolcontinued on the n

Página 74

GE SNPX Protocol – PLC Error Code Tables (cont’d)(PLC generated error codes for the GE Fanuc 90-30, 90-70 and VersaMax SNPX protocolcontinued on the n

Página 75 - Setup Menu

GE SNPX Protocol – PLC Error Code Tables (cont’d)(PLC generated error codes for the GE Fanuc 90-30, 90-70 and VersaMax SNPX protocolcontinued on the n

Página 76 - Information Menu

GE SNPX Protocol – PLC Error Code Tables (cont’d)(PLC generated error codes for the GE Fanuc 90-30, 90-70 and VersaMax SNPX protocolcontinued on the n

Página 77 - Setting – LCD Contrast

GE SNPX Protocol – PLC Error Code Tables (cont’d)PLC Errors for GE SNPX Protocol (Minor-Major) (cont’d)Panel Error CodeP499 Hex ValueDescription0xE005

Página 78

Mitsubishi FX Protocol – PLC Error CodesOnly errors as listed in the C-more Micro-Graphic Panel Error Code Table shown on page A-3can occur when using

Página 79

Conventions UsedWhen you see the “notepad” icon in the left-hand margin, the paragraph to its immediate right will be aspecial note. The word NOTE: in

Página 80 - Setting – Beep

Mitsubishi Q / QnA Series – PLC Error Codes (cont’d)A–22Appendix A: Panel & PLC Error Code TablesA®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Re

Página 81 - Setting – Calibration

Omron Error Code P499 ExplanationThe P499 error code is used to show any errors that are generated by the connected PLC. TheP499 error message include

Página 82 - No[F1] / Yes[F5]

Omron Host Link Protocol – PLC Error Code TableThe following table lists the errors that can be generated by the Omron PLC when using theHost Link pro

Página 83 - Setting – Hourglass

Omron FINS Protocol – PLC Error Code TableThe following table lists the errors that can be generated by the Omron PLC when using theFINS protocol.Note

Página 84 - Setting – Rotation

Omron FINS Protocol – PLC Error Code Table (cont’d)(PLC generated error codes for the Omron FINS protocol continued on the next page.)PLC Error Codes

Página 85 - Test Menu

Omron FINS Protocol – PLC Error Code Table (cont’d)PLC Error Codes for Omron FINSPanel Error CodeP499 Hex ValueDescription0x2507 Unit Error: I/O bus e

Página 86 - TEST MENU

Siemens Error Code P499 ExplanationThe P499 error code is used to show any errors that are generated by the connected PLC. TheP499 error message inclu

Página 87 - Test Menu – Buzzer Test

Siemens PPI Protocol – PLC Error Code TablePLC PDU Header Errors for S7-200 PPIPanel Error CodeP499 Hex ValueDescription0x0001 Hardware Fault.0x0003 O

Página 89 - PLC COMMUNICATIONS

BBC-MORE MICRO-GRAPHICPANELRUNTIME ERRORSAPAPPENDIXAPPENDIXIn This Appendix...Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 90

Product OverviewThe C-more 6” Micro-Graphic panel has a 5.7-inch STN LCD monochrome 320 x 240 dotdisplay. Model EA1-S6ML has five selectable LED-drive

Página 91 - Introduction (cont’d)

B–2Appendix B: C-more Micro-Graphic Panel Runtime Errors®BEA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10IntroductionThe runtime errors dete

Página 92 - CLICK PLC

INDEXAAccessories, 3–2EA-6-COV2, 3–2, 3–15EA-MG-PGM-CBL, 3–2, 3–6, 3–7EA-MG-PGMSW, 3–2EA-MG6-BZ2, 3–2, 3–9EA-MG6-BZ2P, 3–2, 3–11, 3–12Agency App

Página 93

notepad, 1–3EEnclosure Clearances, 1–10Enclosure Thickness, 2–5Error Code P499 Explanation, A–5Allen-Bradley, A–6DirectLOGIC, A–5GE, A–11Modbus

Página 94 - AutomationDirect CLICK PLC:

LLost Firmware – Red ‘Update Mode’ Screen Displayed, 8–4Low-Power Mode, 4–5, 5–10, 5–17, 8–3MMaintenance, 7–2Check Operating Environment, 7–2Check

Página 95

Adjust Display Contrast, 3–5Analog Meter, 3–4Bar Meter, 3–4Bitmap Button, 3–4Circle, 3–4Dynamic Bitmap, 3–5Dynamic Text, 3–5Frame, 3–4Function

Página 96 - Example:

Allen-Bradley PLCs, 6–13AutomationDirect CLICK PLC, 6–9DirectLOGIC DL05, DL06, D0-DCM Module & DL105 PLCs, 6–9DirectLOGIC DL205 PLCs, D2-DCM Mo

Página 97 - RJ12 - 6 pin

SSafety Guidelines, 4–2Serial Number and Date Code format, 1–5Setting Menu, 5–7Backlight, Model EA1-S6ML, 5–8Backlight, Model EA1-S6MLW, 5–9Beep,

Página 98 - K-sequence

Troubleshooting, 8–2C-more Micro-Graphic Panel does not Power up, 8–2Powered from 12-24 VDC, 8–2Powered from 5 VDC, 8–2Display is Blank, 8–2Displ

Página 101 - Allen-Bradley PLCs

Part Number KeyPanel Part Number KeyThe C-more 6” Micro-Graphic panel part numbers consist of the following:Bezel Part Number KeyThe optional C-more 6

Página 103 - Cables from AutomationDirect

EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/101–6Chapter 1: Getting Started1®Quick Start StepsStep 1 – Unpack and Inspecta.) Unpack the C-m

Página 104

EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/101–7Chapter 1: Getting Started1®Step 2 – Install Optional Hardware AccessoriesBelow is an exam

Página 105 - Direct LOGIC:

Step 3 – Become Familiar with Available Communication PortsThe C-more 6” Micro-Graphic panel includes a built-in RS-232 serial communications portdesi

Página 106

EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/101–9Chapter 1: Getting Started1®Step 4 – Install C-more 6” Micro-Graphic PanelThe C-more 6” Mi

Página 107

EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/101–10Chapter 1: Getting Started1®Enclosure ClearancesA 1.2” [30mm] minimum clearance is requir

Página 108

EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/101–11Chapter 1: Getting Started1®Step 5 – Install the Programming Software and Develop a Proje

Página 109 - Allen-Bradley:

EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Chapter 1: Getting Started1®1–12Step 6 – Connect C-more 6” Micro-Graphic Panel to ComputerNOT

Página 110

EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/101–13Chapter 1: Getting Started1®Step 7 – Providing Power to the C-more 6” Micro-Graphic Panel

Página 111

EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/101–14Chapter 1: Getting Started1®Step 8 – Accessing the C-more 6” Micro-Graphic Panel Setup Sc

Página 112 - Mitsubishi:

Step 9 – Choose C-more 6” Micro-Graphic Panel to PLC Protocol & CablesCable Description Cable Part No.Cables used with serial Port1AutomationDirec

Página 113

Graphic Panel - 6 InchHARDWARE USER MANUALPlease include the Manual Number and the Manual Issue, both shown below,when communicating with Technical Su

Página 114 - Diagram 2

Step 10 – Connect C-more 6” Micro-Graphic Panel to PLCConnect the serial communications cable between the C-more Micro-Graphic panel and thePLC. The p

Página 115 - Diagram 4

SPECIFICATIONSCHCHAPTER22CHAPTERIn This Chapter...Available Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 116 - Diagram 6

2–2Chapter 2: Specifications2®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Available ModelsThe C-more 6” Micro-Graphic panels expand the n

Página 117 - Diagram 8

Model SpecificationsSpecification table continued at the top of the next page.2–3Chapter 2: Specifications2EA1-MG6-USER-M Hardware User Manual, 1st Ed

Página 118 - Diagram 10

2–4Chapter 2: Specifications2®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Model Specifications (cont’d)Specifications (cont’d)Screen Obje

Página 119 - Diagram 12

Panel Dimensions2–5Chapter 2: Specifications2EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®6.295[159.9]6.850[174.0].236[6.0]1.453[36.9]1.6

Página 120 - Diagram 14

2–6Chapter 2: Specifications2®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Communications PortsNOTE: The panel has one built-in RJ12 seria

Página 121 - Diagram 16

2–7Chapter 2: Specifications2EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®Chemical CompatibilityThe C-more Micro-Graphic panels are built

Página 122

2–8Chapter 2: Specifications2®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Chemical Compatibility (cont’d)Table continued at top of next p

Página 123

2–9Chapter 2: Specifications2EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®Chemical Compatibility (cont’d)Table continued at top of next p

Página 125

2–10Chapter 2: Specifications2®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Chemical Compatibility (cont’d)Table continued at top of next

Página 126

2–11Chapter 2: Specifications2EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®Chemical Compatibility (cont’d)Table continued at top of next

Página 127 - MA IN TENA NCE

EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/102–12Chapter 2: Specifications2®Chemical Compatibility (cont’d)Table continued at top of next

Página 128 - UTOMATIONDIRECT PLC’s

2–13Chapter 2: Specifications2EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®Chemical Compatibility (cont’d)Table continued at top of next

Página 129 - Check Physical Conditions

Chemical Compatibility (cont’d)Table continued at top of next page.2–14Chapter 2: Specifications2®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C,

Página 130 - Chapter 7: Maintenance

2–15Chapter 2: Specifications2EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®Chemical Compatibility (cont’d)Table continued at top of next

Página 131 - Cleaning the Display Screen

Chemical Compatibility (cont’d)2–16Chapter 2: Specifications2®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10ChemicalsScreen Sheet – PC[Dens

Página 132 - Check Project Functionality

ACCESSORIESCHCHAPTER33CHAPTERIn This Chapter...Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 133

Accessories3–2Chapter 3: Accessories3®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Micro-Graphic Panel AccessoriesPart Number DescriptionE

Página 134

C -more Micro-Graphic Programming SoftwareC-more®Micro-Graphic Programming Software is aspin-off of its powerful sibling C-more Touch Panel. Itoffers

Página 135 - TROUBL ESHOOT ING

 WARNING Thank you for purchasing automation equipment from Automationdirect.com®, doing business as,AutomationDirect. We want your new automation e

Página 136 - Troubleshooting

3–4Chapter 3: Accessories3®Micro-Graphic Programming Software (cont’d)C-more Micro-Graphic Panel Objects continued at top of next page.EA1-MG6-USER-M

Página 137 - No User Program

3–5Chapter 3: Accessories3EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®Micro-Graphic Programming Software (cont’d)C-moreMicro-Graphic Pan

Página 138 - Updating Firmware

3–6Chapter 3: Accessories3®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10USB to RS-232 Programming Cable AssemblyUsing the C-more Micro-Gra

Página 139 - Chapter 8: Troubleshooting

3–7Chapter 3: Accessories3EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®USB to RS232 Programming Cable Assembly (cont’d)USB to RS232 Conve

Página 140

3–8Chapter 3: Accessories3®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/1020-Button Landscape (Horizontal) Keypad BezelThe 20-button keypad

Página 141

3–9Chapter 3: Accessories3EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®20-Button Landscape (Horizontal) Keypad Bezel (cont’d)20-Button Ke

Página 142 - Panel & PLC Error Codes

20-Button Horizontal (Landscape) Keypad Bezel (cont’d)3–10Chapter 3: Accessories3®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10C-more 6 In

Página 143 - Panel Errors

3–11Chapter 3: Accessories3EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®21-Button Portrait (Vertical) Keypad BezelThe 21-button keypad be

Página 144 - Electrical Noise Problems

21-Button Vertical (Portrait) Keypad Bezel (cont’d)3–12Chapter 3: Accessories3®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/1021-Button Keyp

Página 145 - REPLACEMENT PARTS

3–13Chapter 3: Accessories3EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®21-Button Vertical (Portrait) Keypad Bezel (cont’d)3. Use (8) Bez

Página 146 - Replacement Parts

 ADVERTENCIAGracias por comprar equipo de automatización de Automationdirect.com®. Deseamos que su nuevo equipo deautomatización opere de manera seg

Página 147 - Chapter 9: Replacement Parts

D-SUB 15-pin 90-degree Communication Port AdapterThe EA-ADPTR-4 adapter plugs into the 15-pin serial port on the rear of the 6” panel toallow a PLC co

Página 148

3–15Chapter 3: Accessories3EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®Clear Screen OverlayOptional clear screen overlay used to protect

Página 150 - Introduction

44INSTALLATION & WIRINGCHCHAPTERCHAPTERIn This Chapter...Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 151

Safety GuidelinesNOTE: Products with CE marks perform their required functions safely and adhere to relevant standards asspecified by CE directives pr

Página 152 - Entivity Modbus RTU

IntroductionThe installation and wiring of C-more 6” Micro-Graphic panels require selecting an appropriatelocation for the panel, laying out the cutou

Página 153 - Description

4–4Chapter 4: Installation and Wiring4®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Panel Cutout Dimensions (all models)The C-more 6” Micr

Página 154 - P499: Recv. Err Code F017

4–5Chapter 4: Installation and Wiring4EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®Wiring GuidelinesWARNING: To minimize the risk of pote

Página 155

Wiring Guidelines (cont’d)Panel Powered from AutomationDirect PLC via Communications CableNOTE: Maximum cable length when the panel is powered via a P

Página 156

4–7Chapter 4: Installation and Wiring4EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®Wiring Guidelines (cont’d)Panel Powered from an extern

Página 157

 AVERTISSEMENT Nous vous remercions d'avoir acheté l'équipement d'automatisation de Automationdirect.com®, en faisant desaffaires com

Página 159 - P499: Recv. Err Code 020C

In This Chapter...Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5–2Access

Página 160

®Chapter 5: System Setup Screens5–2IntroductionThe C-more®Micro-Graphic panels include a series of built-in System Setup Screens thatallow the user to

Página 161

Accessing the System Setup ScreensTo access the Setup Menu of the panel System Setup Screens, press the panel’s BAK [F1] andENT [F5] function keys sim

Página 162

System Setup Screens Flowchart5–4Chapter 5: System Setup Screens5®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Setup Menu[pg. 5-5]1. Infor

Página 163

5–5Chapter 5: System Setup Screens5EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®Setup MenuTo navigate the different selections under the

Página 164

Information MenuPressing ENT [F5] withMemory highlightedwill show the totalmemory available,memory usage and freememory available forthe project.Press

Página 165

5–7Chapter 5: System Setup Screens5EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®Setting MenuUse the UP [F3] and DWN [F4] function keys to

Página 166

Setting – Backlight, Model EA1-S6MLWith Backlighthighlighted, pressENT [F5] to showthe currentbacklight screencolor. For modelEA1-S6ML, thedefault is

Página 167

5–9Chapter 5: System Setup Screens5EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®Setting – Backlight, Model EA1-S6MLWWith Backlighthighlig

Página 169

Setting – BeepWith Beephighlighted, pressENT [F5] to showthe current value forthe internal beeper.The default is ON.The UP [F3] andDWN [F4] functionke

Página 170

Setting – CalibrationWith Calibrationhighlighted, pressENT [F5] to bringup the firstcalibration screen asshown on the right.Touch the “cross” inthe up

Página 171 - P499: Recv. Err Code 0016

Setting – Clear User MemoryWith Clear UserMemoryhighlighted, pressENT [F5]. You willbe given the choiceto either proceedwith clearing theuser memory b

Página 172

5–13Chapter 5: System Setup Screens5Setting – HourglassThe Hourglassselection listed underthe Setting menu canbe used to eitherdisable the display oft

Página 173

5–14Chapter 5: System Setup Screens5®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Setting – RotationWith Rotationhighlighted, pressENT [F5

Página 174

5–15Chapter 5: System Setup Screens5Test MenuUse the UP [F3] and DWN [F4] function keys to scrollthrough the list of tests. The BAK [F1] function key

Página 175

Test Menu – Serial Port2 - Loop Back TestWith Serial Port2 -Loop Back Testhighlighted, pressENT [F5] to bringup the screen shownto the right. At thisp

Página 176

5–17Chapter 5: System Setup Screens5Test Menu – PLC Enquiry TestWith PLC EnquiryTe st highlighted,press ENT [F5] tobring up the screenshown to the rig

Página 177

5–18Chapter 5: System Setup Screens5®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Test Menu - Touch Panel TestWith Touch Panel Testhighlig

Página 178

66PLC COMMUNICATIONSCHCHAPTERCHAPTERIn This Chapter...Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 179

TABLE OF CONT ENTSChapter 1: Getting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1–1Introduction . . . . . . . . . . .

Página 180

6–2Chapter 6: PLC Communications6®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10IntroductionThe C-more®6” Micro-Graphic panels are capable

Página 181

Introduction (cont’d)The panel can also be connected to more than one PLC by using RS-422 or RS-485 wired ina multi-drop configuration. Port1 and Port

Página 182

C-more 6” Micro-Graphic Communication Ports6–4Chapter 6: PLC Communications6®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10Port2Port2Panel

Página 183

6–5Chapter 6: PLC Communications6C-more 6” Micro-Graphic Communication Ports (cont’d)NOTE: Only one of the communication ports can be used with a conn

Página 184

DirectLOGIC PLCs Password ProtectionNOTE: DirectLOGIC PLCs support multi-level password protection of the ladder program. This allowspassword protecti

Página 185

6–7Chapter 6: PLC Communications6PLC Compatibility and Connection Charts (cont’d)Direct LOGIC PLCs RS-422A/RS-485A:When using the RS-422A/RS-485A comm

Página 186

6–8Chapter 6: PLC Communications6®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10How to use the PLC Compatibility and Connection Charts1.) F

Página 187

6–9Chapter 6: PLC Communications6EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10®AutomationDirect CLICK PLC,DirectLOGIC DL05, DL06, D0-DCM M

Página 188

6–10Chapter 6: PLC Communications6®EA1-MG6-USER-M Hardware User Manual, 1st Ed. Rev C, 09/10DirectLOGIC DL205 PLCs, D2-DCM Module and WINPLCPanel Powe

Página 189

6–11Chapter 6: PLC Communications6DirectLOGIC DL305 PLCs and D3-DCM ModulePanel Powered via external power supply, Port1 or Port2 CommunicationsPLC Co

Comentários a estes Manuais

Sem comentários